00.23
Integral ABS Performing bleed test
with BMW MoDiTeC
d Warning:
Self-diagnosis is not performed unless both brake
levers are in their fully released positions. Prior
to conclusion of the self-diagnosis, only RESIDUAL
BRAKING FUNCTION is available.
Perform BMW Integral ABS self-diagnosis:
•
Release the brake levers, if necessary.
•
Switch on the ignition.
•
With the ignition switched on, bed in the brake
pads against the brake discs.
ABS warning light.............................flashes at 4 Hz
General warning light ........................................ ON
– Self-diagnosis is in progress
ABS warning light.............................flashes at 1 Hz
General warning light ....................................... OFF
– Self-diagnosis successfully completed.
Perform bleed test with BMW MoDiTeC:
•
Remove front and rear seats.
•
Connect the BMW MoDiTeC to the diagnosis
connector.
d Warning:
When performing maintenance and repair work on
BMW Integral ABS, never pump quickly or vigorous-
ly.
•
Perform bleed test.
•
Perform all requisite repair work.
Perform BMW Integral ABS pull-away test:
•
When a speed of 5 km/h (3 mph) is reached, the
ABS warning light must go out.
L Note:
The ABS warning light and the general warning light
must both be OFF after successful self-diagnosis
and the pull-away test.
Final inspection and function check
•
Clutch
•
Check gear shift action.
•
Handbrake and foot brake
•
Check lights and signalling equipment:
– Front and rear parking lights
– Instrument lighting
– Low and high headlight beams, headlight flasher
– Fog lamps
– Brake light (operate brake at front and rear)
– Turn signals left/right
– Hazard warning lights
– Horn
– Telltale and warning lights
– Instruments
•
Check operation of optional extras.
•
If necessary, take the motorcycle for a test ride.
•
Confirm pre-delivery check in Service and Tech-
nical Booklet.
•
See “Checking motorcycle for damage” if defects
are found.
Final cleaning
•
Clean the motorcycle.
L Note:
Do not use a steam or high-pressure water jet. The
high steam or water pressure could damage seals,
the hydraulic system or electrical components.